Call for tenders Services
Framework contract for maintenance of NEA/emergency power/SB installations
Notice published in German. The AI analysis summarises it for you in your language.
Applications due in 25 days — 17 November 2026 at 11:00
“I want this contract”: tracking, reminders and a bid file prepared by AI (eligibility, schedule, cover letter, technical proposal).
- Public buyer
- Flughafen Köln/Bonn GmbH
Köln - Place of performance
- Köln
- Form
- Framework agreement
Multi-year contract: the buyer places orders as needs arise. - Procedure
- Competitive negotiated procedure
You first submit an application; shortlisted candidates bid, then negotiate with the buyer. - Publication
- 16 October 2026
- Notice language
- German
AI analysis: go for it or not?
Summary in English, criteria, documents to provide and a GO / NO GO verdict in one minute.
Unlimited analyses during the 14-day Pro trial, no card needed.
Description
Auf dem Flughafen Köln-Bonn befinden sich verschiedene Notstrom- und Sofortbereitschaftsanlagen (SB). Für diese Anlagen soll eine Wartung/Instandhaltung angeboten werden. Die Wartung/Instandhaltung der NEA/Notstrom/SB-Anlagen erfolgt auf Grundlage der DIN 31051.
Folgende Anlagen sind vorhanden: 1.0) Energiezentrale Gebäude I E: In der Maschinenhalle der Energiestation IE sind folgende Aggregate installiert: 1.1) 4 Stück SB-Aggregate mit einer Nennleistung von je 800 kVA, Dieselmotor MTU 8V396, Nennleistung 690 kW, 3 to-Schwungmasse mit 2 Stück Stehlager, 1 Stück Magnetkupplung, Generator AvK, DSG 62L, 1-4, Nennleistung 800 kVA Baujahr 1994; 1.2) 3 Stück Notstrom-Aggregate mit einer Nennleistung von je 800 kVA, Dieselmotor MTU 8V396, Nennleistung 690 kW, Generator AvK, DSG 62L, 1-4, Nennleistung 800 kVA, Baujahr 1994; 2.0) Frachthalle FedEx: Im Erdgeschoss der Frachthalle FedEx ist folgendes Aggregat installiert: 1 Stück Notstromaggregat, bestehend aus: --Dieselmotor Volvo Penta TAD 1641GE, Nennleistung 473 kW --Generator Marelli MJB 355SA4, Nennleistung 500 kVA Baujahr 2009; 3.0) Brandschutzwache 2 An der Brandschutzwache 2 ist folgendes, freistehendes Container-Aggregat installiert: --Dieselmotor Volvo Penta TAD 732GE, Nennleistung 204 kW --Generator mecc alte, ECO 38-2SN/4, Nennleistung 200 kVA Baujahr 2007, Gesamte Aggregateleistung lt. Typenschild = 185 kVA; 4.0) Mobiles Aggregat Im Bereich der Energiezentrale IE befindet sich ein mobiles Stromerzeugungsaggregat mit folgenden Daten: --Dieselmotor IVEKO Typ GE8361SRI2500A --Generatorleistung 165 kVA
CPV codes
European codes that classify what the contract is about. They are how we find the tenders for your trade.
50532000 31682530 50532300
Partners and subcontractors
Contract too big or too broad for you alone? Bid as a temporary consortium, or offer your services as a subcontractor.
Create your free account to see who is looking for a partner on this contract, and to register.
Similar contracts already awarded
| Contract | Winner | Amount |
|---|---|---|
| Wartungsvertrag TE-Care für Tecan-Roboter Hessisches Landeskriminalamt · 13 October 2026 |
Tecan Deutschland GmbH | – |
| Rahmenverträge über die Wartung und Instandhaltung von Ladeinfrastruktur im öffentlichen und privaten Raum Berliner Wasserbetriebe · 5 October 2026 |
synfis Service GmbH | – |
| AMEV-Verträge Raumlufttechnische Anlagen, Ventilatoren, Kälteanlagen und dezentrale Teilklimageräte Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau · 2 October 2026 |
Apleona Wolfferts GmbH | €621,080 |
| Rahmenvertrag zur Wartung und Instandhaltung von Drucklufterzeugungsanlagen inkl. Rufbereitschaft Stromnetz Berlin GmbH · 2 September 2026 |
Förster Drucklufttechnik GmbH | €1 |
| Instandsetzung von Getriebe und Motoren der ST14 HEAG mobilo GmbH · 17 August 2026 |
Alstom Transport Deutschland GmbH | – |
Source : TED – Office des publications de l'Union européenne © Union européenne, données retraitées. Reference 717032-2026.